MEASURE INSIDE WIDTH (Cycle 425, DIN/ISO: G425) 16.9

16

TNC 320 | User's Manual Cycle Programming | 3/2014

389

16.9

MEASURE INSIDE WIDTH (Cycle 425,
DIN/ISO: G425)

Cycle run

Touch Probe Cycle 425 measures the position and width of a slot
(or pocket). If you define the corresponding tolerance values in the
cycle, the TNC makes a nominal-to-actual value comparison and
saves the deviation value in a system parameter.

1 Following the positioning logic, the TNC positions the touch

probe at rapid traverse (value from

FMAX column) (see

"Executing touch probe cycles", page 286) to touch point

1

. The

TNC calculates the touch points from the data in the cycle and
the safety clearance from the

SET_UP column of the touch

probe table.

2 Then the touch probe moves to the entered measuring height

and runs the first probing process at the probing feed rate
(column

F). 1. The first probing is always in the positive direction

of the programmed axis.

3 If you enter an offset for the second measurement, the TNC

then moves the touch probe (if required, at clearance height)
to the next starting point

2

and probes the second touch point.

If the nominal length is large, the TNC moves the touch probe
to the second touch point at rapid traverse. If you do not enter
an offset, the TNC measures the width in the exact opposite
direction.

4 Finally the TNC returns the touch probe to the clearance height

and saves the actual values and the deviation value in the
following Q parameters:

Parameter number

Meaning

Q156

Actual value of measured length

Q157

Actual value of the centerline

Q166

Deviation of the measured length

Please note while programming:

Before a cycle definition you must have programmed