beautypg.com

HEIDENHAIN TNC 320 (77185x-01) Cycle programming User Manual

Page 297

background image

BASIC ROTATION over two holes (Cycle 401, DIN/ISO: G401) 14.3

14

TNC 320 | User's Manual Cycle Programming | 3/2014

297

Compensation Q402: Define whether the TNC
should set the measured misalignment as basic
rotation or should align via rotating the rotary table:

0

: Set basic rotation

1

: Rotate the rotary table

If you specify rotating the rotary table, the TNC
does not save the measured misalignment, even if
you have defined a table row in parameter

Q305.

Set to zero after alignment Q337: Define whether
the TNC should set the display of the aligned rotary
axis to 0:

0

: Do not set the rotary axis display to 0 after

alignment

1

: Set the rotary axis display to 0 after alignment.

The TNC only sets the display to 0 if you have set
Q402=1.