Switch-on, traversing the reference points, 0 è 1 – HEIDENHAIN ND 710 v.3 User Manual
Page 9

9
Switch-On, Traversing the Reference Marks
ENT...CL
Turn on power (switch located on rear panel).
REF and decimal points in status display blink.
Confirm reference traverse mode. REF remains
on continuously. Decimal points blink.
Cross over the reference marks in all axes (in any
sequence). Each axis display becomes active
when its reference mark is crossed over.
ENT
Crossing over the reference marks stores the last relationship
between axis slide positions and display values for datum points 1 and
2 in nonvolatile memory.
Note that if you choose not to traverse the reference marks (by
clearing the dialog ENT ... CL with the CL key), this relationship will be
lost if the power is interrupted or when the unit is switched off.
Switch-On,
Traversing
the
Reference
Marks
If you wish to use multipoint axis error compensation you
must traverse the reference marks (see Multipoint axis error
compensation)!
0 è 1
Bateil1.pm6
07.11.2001, 09:38
9