Error messages – HEIDENHAIN ND 710 v.3 User Manual
Page 29

29
To erase error messages:
After you have removed the cause of error:
➤ Press the CL key.
Error Messages
Message
Cause and effect
SIGNAL X
Encoder signal is too small,
e.g. when an encoder is
contaminated.
PROB. ERROR
Before touching off on the
workpiece, the tool must move
by a distance of at least 0.2 mm.
ERR. REF. X
The spacing of the reference
marks as defined in P43 is not
the same as the actual spacing.
FRQ. ERR. X
The input frequency for this
encoder input is too high. This
can occur when the scale is
moved too fast.
ERR. MEMORY
Check sum error: Check the
datum, operating parameters and
compensation values for multi-
point axis error compensation.
If the error recurs, contact your
service agency!