P41.1 to P41.3
Linear axis error compensation
Input range (µm):
-99999 to +99999
Factory default setting:
0
Example: Displayed length
Ld = 620.000 mm
Actual length (as determined for example with
the VM 101 from HEIDENHAIN)
La = 619.876 mm
Difference
DL = L
a
L
d
= 124 µm
Compensation factor k:
k = DL/Ld = 124 µm/0.62 m = 200 [µm/m]
P42.1 to P42.3 Backlash compensation
Input range (mm):
+9.999 to –9.999
Default setting:
0.000 = no backlash
compensation
A change in direction might cause a clearance between
rotary encoder and table. This is referred to as backlash.
Positive backlash: The rotary encoder is ahead of the table.
The distance traversed by the table is too short (entry of
positive value).
Negative backlash: The rotary encoder follows the table. The
distance traversed by the table is too large (entry of negative
value).
P43.1 to P43.3 Reference marks
One reference mark
SINGLE REF.M.
Distance-coded with 500 SP
500
SP
Distance-coded with 1000 SP
1000
SP
Distance-coded with 2000 SP
2000
SP
Distance-coded with 5000 SP
5000
SP
(SP: signal period)
P44.1 to P44.3 Reference mark evaluation
Evaluation
REF. X ON
No evaluation
REF. X OFF
P45.1 to P45.3 Encoder monitoring
Amplitude and frequency
monitoring
ALARM ON
No monitoring
ALARM OFF
P48.1 to P48.3 Activate axis display
Axis display active
AXIS ON
Not active
AXIS OFF
P70 Number of datums
2 datums
2 DATUM PT.
9 datums
9 DATUM PT.
P80 Function of the CL key
Reset to zero with CL
CL...RESET
No reset to zero with CL
CL......OFF
P81 Function of the R+/- key
The R+/- key divides the actual
R+/- 1/2
value by two
No division of the actual value
R+/- OFF