beautypg.com

HEIDENHAIN ND 200 User Manual

Page 21

background image

ND 200

Installation Instructions

en

23

Pin

Function

23 I Contact: Measured value output,

see Figure 1 in "L" in the Appendix

24 I Ignore reference mark signals (X2, optional)
25 I Enable or disable REF mode (current REF status is

changed)

For pin layout, see "L" in the Appendix.

Switching inputs for measured value output

See Figure 1 in "L" in the Appendix.
The respective switching input is active when a Low signal

U

L

is applied (contact or pulse to 0 V).

Input signals:
Signal

Value

Internal

pull-up resistor

1 k

Ω, active Low

Activation

Trigger by making contact against

0 V or by low-level signal over TTL

logic device

Delay time for

preset/reset

t

V

≤ 2 ms

Minimum pulse du-

ration for all signals

(except for pin 22

and pin 23)

t

min

≥ 30 ms

For signal level of inputs, see "Specifications", page 24.

Open-collector outputs

See Figure 2 in "L" in the Appendix.
The unit features open-collector outputs that switch to 0 V

(= active Low).

Output signals:
Signal

Value

Open-collector out-

puts

Active Low

Delay until signal out-

put

t

V

≤ 20 ms

Signal duration of ze-

ro crossover, trigger

limit A1, A2

t

0

≤ 180 ms

For signal level of outputs, see "Specifications", page 24.

4.7

Only ND 287: Installing optional
expansion modules

For information on the location of the slots, see "Rear

panel", page 20.

Installing expansion modules

See "D" on the front fold-out page.

1
2

Ethernet expansion module
Analog module or encoder module

Switch the unit off and disengage the power plug.
Loosen the Torx screws of the selected input.
Remove the cover from the slot, or remove any module
that might be inserted.
Insert the new input assembly.
Re-tighten the Torx screws:
Tightening torque 1.5 Nm.

Connecting connectors

Connect the connector tightly to the respective
connection on the rear panel.
X1, X2: If the connectors include mounting screws, do
not overtighten them.
X26(X27): Insert the terminal of the RJ-45 connector so
that it engages.

Pin layouts

X1, X2: For connection of analog module, see "M" in the
Appendix.
X1, X2: For connection of the 11 µA

PP

/1 V

PP

/EnDat 2.1

module, see "H" in the Appendix.
X26(X27): For connection of the Ethernet module, see
"K" in the Appendix.

Vacant pins or wires must not be used.