beautypg.com

Volume configuration, Volume configuration -5, Rosemount 3300 series – Emerson Guided Wave Radar Level and Interface Transmitters 3300 User Manual

Page 57: Reference manual

background image

Reference Manual

00809-0100-4811, Rev CA
February 2006

4-5

Rosemount 3300 Series

Volume Configuration

For volume calculations you can choose one of the standard tank shapes or
the strapping option. Choose None if volume calculation is not used.

Tank Type

You can choose one of the following options:

Strap table

Vertical Cylinder

Horizontal Cylinder

Vertical Bullet

Horizontal Bullet

Sphere

None

Strapping Table

Use a strapping table if a standard tank type does not provide sufficient
accuracy. Use most of the strapping points in regions where the tank shape is
non-linear. A maximum of 10 points can be added to the strapping table.

Figure 4-3. Strapping points

Actual tank bottom may look like this.

Using only 3 strapping points results in a level-to-volume profile
that is more angular than the actual shape.

Using 6 of the points at the bottom of the tank yields a
level-to-volume profile that is similar to the actual tank bottom.

S

T

RAPPI

NG PO

INT

S