beautypg.com

European atex directive information, Intrinsic safety, Rosemount 3300 series – Emerson Guided Wave Radar Level and Interface Transmitters 3300 User Manual

Page 131: Reference manual

background image

Reference Manual

00809-0100-4811, Rev CA
February 2006

B-3

Rosemount 3300 Series

EUROPEAN ATEX
DIRECTIVE
INFORMATION

Intrinsic Safety

The Rosemount 3300 Series Guided Wave Radar Level and Interface
Transmitter that has the following label attached has been certified to comply
with Directive 94/9/EC of the European Parliament and the Council as
published in the Official Journal of the European Communities No. L 100/1 on
19-April-1994.

Figure B-1. Approval Label
ATEX (BASEEFA) and Name
Plate

The following information is provided as part of the label of the transmitter:

Name and address of the manufacturer (Rosemount).

CE Conformity Marking

Complete model number

The serial number of the device

Year of construction

Marking for explosion protection:

EEx ia IIC T4 (-50 °C

Ta

+70 °C)

Ui=30 V, Ii=130 mA, Pi=1 W, Ci=0, Li=0

BASEEFA ATEX certificate number: BAS02ATEX1163X

Special Conditions for Safe Use (X):

The apparatus is not capable of withstanding the 500 V test as defined in
clause 6.4.12 of EN 50020. This must be considered during installation.

When used in a potentially explosive atmosphere where the use of
equipment-category 1 apparatus is required, appropriate measures must be
taken to prevent electrostatic discharge.

APP

ROVA

LS-A

TE

X_B

AS_I

1

/N

AMEP

LATE