Table A-15. Environmental Characteristics
Characteristics
Description
Operating Temperature
Requirement:
5
°
to 40
°
C (+41
°
to 122
°
F)
Storage Temperature
Requirement:
-40
°
to 65
°
C (-40
°
to 149
°
F)
Operating Altitude
Requirement:
To 15,000 feet (4572 meters)
Supplemental Data:IEC 950 compliant to 2000 meters
Storage Altitude
Requirement:
To 50,000 feet (15,240 meters)
Vibration
Requirement:
Military Specification: Mil-T-28800D, Class 6
(Non-Operating Only)
Mechanical Shock
Military Specification: Mil-T-28800D, Class 6 (Non-Operating Only)
Transportation
Requirement:
Qualified under NSTA Test Procedure 1A, Category II
(24 inch drop)
Equipment Type
Supplemental Data:Information Technology
Equipment Class
Supplemental Data:Class I
Installation Category
Requirement:
Category 2 Indoor use only
Pollution Degree
Requirement:
Level 2 operating environment
Humidity
Requirement:
Operating 20% - 80%
Non-Operating 8% - 90%
Transportation 5% - 95%
Maximum Wet Bulb Temperature 26
°
Supplemental Data:Do not operate with visible moisture on the circuit
boards
Table A-16. Mechanical Characteristics
Characteristic
Description
Dimensions
Requirement:
Height:
8.750 inches (22.225 centimeters)
Width:
19.000 inches (48.260 centimeters)
Depth:
23.500 inches (59.690 centimeters)
Weight
Requirement:
Net:
70 pounds (31.751 kilograms)
Shipping:
85 pounds (38.555 kilograms)