beautypg.com

Router alarms, Installation, Making alarm connections – Grass Valley NV7512 v.1.3 User Manual

Page 83

background image

NV7512 Audio Router • User’s Guide

73

2. Installation

Making Alarm Connections

Figure 2-34. NV6257 Power Supply Alarms Connection

Router Alarms

The ‘ALARM’ connection on the rear of the NV7512 uses a DE9 connector. An “alarm” or ON
condition occurs when the connection between an alarm pin and Alarm_COM (common) opens.
The alarm turns OFF when the connection between Alarm_COM and the alarm pin closes again.

To create an indicator box, connect to the ‘ALARM’ connection using a DE9 female connector,
wiring as shown in Figure 2-35. Each pin monitors a specific function and activates a specific
alarm.

COM

COM

Customer-supplied

relay contacts NC

Normally OFF, the

LEDs turn on to

indicate failure

Normally ON, the

LEDs turn off to

indicate failure

External Power

30VDC max,

150mA max

GND 1

GND

14

PS1 2

PS1 COM

15

PS2 3

PS2 COM

16

PS3 4

PS3 COM

17

PS4 5

PS4 COM

18

PS5 6

PS5 COM

19

PS6 7

PS6 COM

20

PS7 8

PS7 COM

21

PS8 9

PS8 COM

22

GND 10

GND

23

GND 11

GND

24

GND 12

GND

25

GND 13

NV6257 External Power Supply Alarm, DB25, Female

Connection examples are shown below

for PS6000 power supply modules 3

and 8. Connections may be made for all

8 power supplies in the NV6257 frame.

Typical Circuit 1

Typical Circuit 2

PS3

PS8

PS3

PS8

External Ground

Caution

The power supply for the alarm circuit must not exceed 30VDC. Load resistor
value depends on power supply voltage.

This manual is related to the following products: