Analog signals and signal numbers, Rear connections, Introduction – Grass Valley NV7512 v.1.3 User Manual
Page 21

NV7512 Audio Router • User’s Guide
11
1. Introduction
Module Slots and Rear Connectors
Figure 1-4. Inputs and Outputs, Numbers Assigned (Front View)
Analog Signals and Signal Numbers
The router frame slots have printed labels that list signal numbers corresponding to AES synchro-
nous stereo signals, numbers 1 through 32. This numbering scheme does not correspond to analog
signals.
For AES stereo signals, 32 signals can be supported, matching the labeling for signal numbers on
the router frame. For analog signals, only 16 analog stereo signals are supported, so signals do not
match the 32 signal number labels. The stereo signal is received through input 1, then input 3, then
input 5, and so on, up to 32, skipping every other signal label number in sequence. However, 32
mono signals can be received, matching the router label number scheme.
When routing mono and analog signals, it is recommended that a labeling convention be adopted
and rigorously followed for all mono switching configurations.
Rear Connections
The rear of the NV7512 (Figure 1-5 on page 12) features a back plate containing backplanes for
receiving and distributing signals. Each backplane contains passive connectors that pass the signals
through to active, receiving connections on the input cards and output cards.
An additional backplane, located in the left-hand section of the upper bay, contains four BNC con-
nectors for the monitor card. In the left-hand region and lower, left-hand corner of the frame are
Fan
Fan
Slot A - Crosspoint (Outputs 1-128)
Slot B - Crosspoint (Outputs 129-256)
Slot C - Crosspoint (Outputs 257-384)
Slot D - Crosspoint (Outputs 385-512)
Output
s 132
Output
s 33-64
Output
s 65-96
Output
s 97-128
Output
s 129-160
Output
s 161-192
Output
s 193-224
Output
s 225-256
Output
s 257-288
Output
s 289-320
Output
s 321-352
Output
s 353-384
Output
s 385-416
Output
s 417-448
Output
s 449-480
Output
s 481-512
Control Secondary
Control Primary
Input
s 132
Input
s 33-64
Input
s 65-96
Input
s 97-128
Input
s 129-160
Input
s 161-192
Input
s 193-224
Input
s 225-256
Input
s 257-288
Input
s 289-320
Input
s 321-352
Input
s 353-384
Input
s 385-416
Input
s 417-448
Input
s 449-480
Input
s 481-512
Fan
Monitor