Configuration

Panel Options

By default, all the check box options are unchecked except ‘Src/Dst Immediate Take’. That partic-
ular option is enabled by default.

The ‘Clear Configuration’ button removes all configuration data from the panel. The panel then
has a blank configuration. If you click this button by mistake, you can regain the previously
saved configuration by clicking the ‘Revert to Saved’ button.

The check box options differ under the ‘All Buttons’ model and the ‘Display and Buttons’ model.
The difference is the ‘Page VFD Only’ option which is available only under the ‘Display and
Buttons’ model.

The following items are the checkbox options:

User-Programmable ID.

Allows the Panel ID to be changed locally at the control panel (in menu mode).

Save Preset Default.

Makes ‘Save Preset’ mode active when the panel reverts to its default state (after a Default
State button is pressed, or when the panel is restarted).

A ‘Save Preset’ button is needed only when you want the operator to be able to view or
change the mode.

Hold Preset Default.

Makes “hold” mode active when the panel reverts to its default state (after a Default State
button is pressed, or when the panel is restarted).

Note: a ‘Hold’ button is needed only when you want the operator to be able to view or
change the mode.

Enable Destination Lock.

Check ‘Enable Destination Lock’ so that any ‘Destination Lock’ button on the panel will func-
tion.

Enable Destination Protect.

Check ‘Enable Destination Protect’ so that any ‘Destination Protect’ button on the panel will
function.

Source Master Default.

Makes a control-level source the controlling device (or master device) by default. Otherwise,
the destination is the master by default. (The option is specifically for use with NV9000 series
machine control routers.)

“Source is master” is used for duplication, or broadcast routing, on a machine control level.
“Destination is master” is for machine-to-machine editing. If you do not select the “source
master default” option, you can place a ‘Source is Master’ button on the panel.

Note: a ‘Source is Master’ button is a toggle that reverses the direction of data routing
for devices used in data level (machine control) takes.

Hide sources not configured on this panel.

Causes the names of source devices that are not presently configured for this particular
panel to be effectively hidden. When another panel changes the source to one not config-
ured for this panel, this panel displays asterisks instead.

Deselect all destinations and turn off hold after take.