Editor port jumpers, Model 3000, Communication standard – Grass Valley 2200 User Manual
Page 11: Termination, Editor port jumpers -3, Model 3000 -3, Communication standard -3 termination -3

1-3
Editor Port Jumpers
Editor Port Jumpers
Jumper settings on the Control Processor module must be set as follows for proper
operation of the EDITOR port:
Model 3000
For the Model 3000, the EDITOR port jumpers are located on the Control
Processor module (068906) between the M/E 2 Processor mezzanine board
(068916) and the Serial Communications mezzanine board (068918). See Figure 1-
1. Jumper J71 sets the communication standard (RS-232 or RS-422); Jumper J70 sets
the EDITOR port termination (IN or OUT).
Communication Standard
For
RS-422
, set the two jumpers of J71 to the
DIFF
position (RS-422) as shown
in Figure 1-1. This connects pins 1 and 3 together and pins 2 and 4 together.
For
RS-232
, set the two jumpers of J71 to the
RS232
position. This connects pins
3 and 5 together and pins 4 and 6 together.
Termination
Set the two jumpers of J70 to either the
IN
(terminated) position or the
OUT
(not
terminated) position, depending on the requirements of your system.
If J71 is set for RS-232, Jumper J70 has no effect.
Figure 1-1. EDITOR Port Jumper Settings on Model 3000
(shown set for RS422, terminated)
M/E 2 Processor
Mezzanine Board
(068916)
Serial Communication
Mezzanine Board
(068918)
J70
J71
DIFF
RS232
EDITOR
IN
TERM
OUT
Control
Processor
Module
(068906)
rear
edge
connector
0350-11