Grass Valley Kameleon HD Multi-Function Modules v.2.1.0 User Manual
Page 95

Kameleon HD Instruction Manual
95
Initial Configuration Process Overview
•
Slot Memory
– the slot configuration for each media module is automati-
cally saved periodically (once an hour) to the 2000NET module in that
frame. You may also select the
Learn Module Config
button at any time to
save the current configuration for this slot. The configuration is saved
on the 2000NET module. If the 2000NET module is removed or
powered down, the stored configurations are not saved.
When the
Restore upon Install
box has been checked, the current configu-
ration saved to this slot is saved as slot memory. When the current
module is removed and another module of the same type and software
version is installed, the configuration saved to the 2000NET module
will be downloaded to the new module. The box must be checked
before the current module with the saved configuration is removed.
If a different type of module is installed in this slot, a warning message
will state that the original module type has been replaced with another
module type. In this case, a
Clear
button will appear allowing you to
clear the stored configuration from the previous module.
Note
Uncheck the Restore Upon Install button before downloading new software.
•
Frame Health Reports Link
– select the Frame Health Reports link to open
the 2000NET module Frame Alarm Reporting web page. This web page
allows configuration of the alarms and warnings that are reported to
the external Frame Health Alarm connector on the rear of the 2000T3
frame (not present on the 2000T1 frame).
This web page contains the following sections:
•
Hardware Switch Status
– the Hardware Switch Status section of this
web page displays the current settings of the alarm and warning
configuration DIP switches, S1 and S2, on the 2000NET circuit
board in this frame. These switches allow enabling and disabling of
the overall status reporting information that is provided to the
external Frame Alarm.
•
Output Format for Warnings
– set the Output Format for Warnings on the
external RS-232 Frame Alarm output on the rear of the frame. When
the
Open
radio button is selected, warnings are not reported to the
external frame alarm. Selecting the
Closed
radio button, causes
warnings to be reported in the same manner as alarms.