Power up, Operation indicator leds, Ocess (see – Grass Valley Kameleon HD Multi-Function Modules v.2.1.0 User Manual

Page 17

background image

Kameleon HD Instruction Manual

17

Power Up

Power Up

The front LED indicators are illustrated in

Figure 9

. Upon power-up, the

green PWR LED should light and the yellow CONF LED should illuminate
for the duration of module initialization.

Operation Indicator LEDs

With factory default configuration and valid input and reference signals
connected, the green PWR LED should be on.

Figure 9. Operation Indicator LEDs

A red FAULT LED indicates an error situation and, with the other LEDs,
can indicate the operational conditions presented in

Table 2

.

Table 2. Indicator LEDs and Conditions Indicated

LED

Indication

Condition

FAULT

(red)

Off

Normal operation.

On continuously

Module has detected an internal fault.

Flashing

Frame reference or video input is missing, input does not match manual selection.

COMM

(yellow)

Off

No activity on frame communication bus.

Long flash

Location Command received by the module from a remote control system.

Short flash

The new system configuration is being stored to the module.

CONF

(yellow)

Off

Module is in normal operating mode.

On continuously

Module is initializing, changing operating modes or updating firmware. Simulta-
neous CONF and FAULT LEDs on indicate FPGA load error.

Long flash

Location Command received by the module from a remote control system.

PWR

(green)

Off

No power to module or module’s DC/DC converter failed.

On continuously

Normal operation, module is powered.

8341_03

FAULT LED
COMM LED
CONF LED

POWER LED