Service

Service

The Kameleon HD modules make extensive use of surface-mount tech-
nology and programmed parts to achieve compact size and adherence to
demanding technical specifications. Circuit modules should not be ser-
viced in the field unless directed otherwise by Customer Service.

If your module is not operating correctly, proceed as follows:

Check frame and module power and signal present LEDs.

Verify power at the voltage testpoints at the front of the module and
check Fuse F1 if no voltage is detected (

Figure 78

).

Check for presence and quality of input signals.

Verify that source equipment is operating correctly.

Check cable connections.

Refer to

Figure 9 on page 17

for the location of PWR LED and

Table 2 on

page 17

for proper LED indications.

If the module is still not operating correctly, replace it with a known good
spare and return the faulty module to a designated Grass Valley repair
depot. Call your Grass Valley representative for depot location.

Refer to the

Contacting Grass Valley

at the front of this document for the

Grass Valley Customer Service Information number.

Figure 78. Test Point and Fuse Locations

8341_08r1

F1

Fuse: 2 A FAST, 125 V

J1

JP3

Voltage

Test Points

+12V

+5V

+2.5V

R10

-2.7V

+2.5V

+1.5V

TP 2

GND

-5V

+3.3V

-12V

GRASS VALLEY SD/HD MULTIFUNCTION MODULE

671-6514 –