Service

Service

The Kameleon modules make extensive use of surface-mount technology
and programmed parts to achieve compact size and adherence to
demanding technical specifications. Circuit modules should not be ser-
viced in the field except to check and replace fuses.

Troubleshooting

If your module is not operating correctly, proceed as follows:

Check frame and module power at the front edge testpoints (

Figure 42

).

If power is not present, check the fuse on the +24 V input (

Figure 42

).

Check for presence and quality of input signals.

Verify that source equipment is operating correctly.

Check cable connections.

Figure 42. Location of Module Fuse and Voltage Testpoints

Refer to

Figure 6 on page 13

for the location of PWR LED and

Table 2 on

page 14

for proper LED indications.

If the module is still not operating correctly, replace it with a known good
spare and return the faulty module to a designated Grass Valley repair
depot. Call your Grass Valley representative for depot location.

Refer to the

Contacting Grass Valley

at the front of this document for the

Grass Valley Customer Support Information number.

J12

J12

Voltage

Test Points

+15V

+5V

+3.3V

-5V

-15V

+1.5V

8345_05

Fuse F1, 2A 125 V