beautypg.com

And an, E-mem configuration web page – Grass Valley KAM-ENC-2AES v.4.0.1 User Manual

Page 56

background image

56

KAM-ENC-2AES Instruction Manual

KAM-ENC-2AES Links and Web Pages

E-MEM Configuration Web Page

The E-MEM page provides local operations for learning and recalling con-
figurations into five E-MEM registers. File operations are also available for
saving or loading the learned E-MEM files to and from a hard disk or other
accessible media.

Factory default settings for all channels can be recalled by selecting the

Recall factory settings

button. To return the module to the factory signal

names (such as the signal inputs), select the

Recall factory names

button.

There are two E-MEM view selections:

Standard

and

Advanced

.

In Standard view (

Figure 34

), any one of five learned E-MEMs can be

recalled by selecting the corresponding

Recall

button in the Local Opera-

tions window. This will place the configuration for the entire module into
that E-MEM into the KAM-ENC-2AES. This change will occur immediately
upon recall. The name of the last recalled E-MEM will appear in the top
header of each web page for the module.

To learn an E-MEM select the

Advanced

button in the View Selection section.

This will open the Advanced view (

Figure 35 on page 57

).

Figure 34. E-MEM Web Page (Standard View)