beautypg.com

Frame settings, Sw1 switch (apex plus systems only), Ge 10 – Grass Valley Apex v.2.0 User Manual

Page 99

background image

APEX — Installation and Service Manual

101

Frame Settings

Frame Settings

Note

On all the rotary switches, use the triangular arrowhead for pointing to the
desired setting (not the screwdriver slot).

SW1 Switch (Apex Plus Systems Only)

Switch SW1 (

Figure 44

) applies only to Apex Plus systems. Positions for

setting switch settings for system size and number of chassis with SW1 are
given in

Table 3

Figure 44. SW1 Switch

Table 3. SW1 Switch Settings (Apex Plus Only)

System Size

Number of Chassis

SW_1 Position

(setting applies to all

chassis in system)

512 X 512

2 (1 In + 1 Out)

0

512 X 1024

(1) Rx to (2) Tx

1

512 X 1536

(1) Rx to (3) Tx

2

512 X 2048

(1) Rx to (4) Tx

3

1024 X 0512

(2) Rx to (1) Tx

4

1024 X 1024

(2) Rx to (2) Tx

5

1024 X 1536

(2) Rx to (3) Tx

6

1024 X 2048

(2) Rx to (4) Tx

7

1536 X 0512

(3) Rx to (1) Tx

8

1536 X 1024

(3) Rx to (2) Tx

9

1536 X 1536

(3) Rx to (3) Tx

10

1536 X 2048

(3) Rx to (4) Tx

11

2048 X 0512

(4) Rx to (1) Tx

12

2048 X 1024

(4) Rx to (2) Tx

13

2048 X 1536

(4) Rx to (3) Tx

14

2048 X 2048

(4) Rx to (4) Tx

15

2

3

4

5

6

7

8

9

10

11

12

13

14 15

1

0

SW1