54

APEX — Installation and Service Manual

Section 2 — Planning Guide

Output Monitoring

Note

Output Monitoring applies only to standard Apex systems.

Output monitoring allows verification of switcher performance without
interrupting normal operations. A separate internal switching system is
used to switch the selected output signal to the Output Monitor connector.
See

Figure 19

.

Figure 19. Example of Output Monitor Connection

For a standard Apex system, using a standard system control panel, the
operator picks an output as usual—in this case, the Output Monitor. (The
physical number of the Output Monitor connector is determined by the
Max Size switch setting plus 1) The operator then selects an input, but this
input is actually one of the switcher outputs.

Two connector sets are provided on each chassis: OP MON A, which corre-
sponds to the A Matrix board; and OP MON B, which corresponds to the
optional B (secondary) Matrix board. Within each set are two connectors: a
BNC type for 75 Ohm cabling, and a 9-pin D female type for 110 Ohm
cabling. Pinouts for the D connector are shown in the Planning and Installa-
tion Manual
. Note that some pins on this connector are used for 110 Ohm
AES Reference cabling.

For example, in a

1

based system, to monitor Output #1 in a 256 x 256

system, route Source #1 to Output #257.

Jupiter Control System

Switcher Control Panel

AES REF B

HIGHEST

A

MC A

LOWEST

OUT

IN

OUT

OP MON A

AES REF A

HIGHEST

2

1

P

X

E

4

3

EXPANSION

B

OUT

OUT

MC B

LOWEST

IN

OP MON B

P

E

X

VID REF A

1

2

EXPANSION

3

4

VID REF B

1536

1792

2048

1280

1024

768

512

256

Crosspoint bus

MPK bus

Monitoring Station