beautypg.com

Level – Grass Valley Apex v.2.0 User Manual

Page 105

background image

APEX — Installation and Service Manual

107

Jupiter Control

2.

Set Level switches:

Two back-panel rotary switches shown in

Figure 50

are used to set the

level address of the router.

Figure 50. Level Switches

For Jupiter VM-3000 control

:

Super

Crosspoint bus settings must be used.

The left-hand switch is turned to the appropriate most significant bit on
the

Super

side of the switch; the least significant bit is set on the right

switch. For example, to set the switcher level at

32

(the factory default

for serial digital video) the left switch would be set at

Super 32

and the

right switch set to

0

.

Note

Systems larger than 512x512 cannot be controlled by VM-3000.

For Jupiter CM-4000 control:

Either

Super

or

Ultra

Crosspoint bus settings can

be used; however, systems larger than 512 x 512 must use

Ultra

Cros-

spoint bus settings. For these settings, the left-hand switch is turned to
the appropriate most significant bit on the

Ultra

side of the switch; the

least significant bit is set on the right switch. For example, to set the
switcher level at

32

(the factory default for serial digital video) the left

switch would be set at

Ultra 32

and the right switch set to

0

.

3.

For synchronous switching on all outputs, the same sync signal must be
sent to the Jupiter and to the Apex.

4.

Connect the Status LAN as required. See

Figure 51 on page 110

.

5.

Refer to the Jupiter VM-3000 System Controller Installation and
Operation Manual, part number 04-045707-002 or the Jupiter CM-4000
System Controller Installation and Operation Manual, part number
0718261xx for control system installation details.

LEVEL

SUPER

ULTRA

0

0

0

1

2

3

4

5

6

7

8

9

10

11

12

13

14 15

16

16

32

32

48

48

64

64

80

80

96

96

112

112