beautypg.com

Environmental, Physical, Alarm – Grass Valley Apex v.2.0 User Manual

Page 61: Ac power input, Fiber extenders, Apx-fbr-ext

background image

APEX — Installation and Service Manual

63

Specifications

Environmental

0° to +35° C

10 to 90%, Non-condensing

Physical

Chassis: 19.25 inches (11 RU) high x 19 in. wide x 11 in. deep
(489 x 483 x 279 mm)

Weight: 63 lbs. (29 kg) fully stuffed

Alarm

The alarm connector is a BNC type and meets SMPTE 269M-1999.

AC Power Input

Mains connection: IEC connector, separate mains input for each power
supply module

Voltage range: 100 to 240 V, 50-60 Hz, universal, auto-ranging

Inrush current for 75 Ohm system: 10.2A

Inrush current for 110 Ohm system: 9.4A

Total power: 163 Watts

APEX Plus

Total Power: Input frame 130 W, Output frame 205 W.

Fuses: 2.25 A required for 110-120 V operation. 1.6 A required for 220-240 V
operation.

Fiber Extenders

Fiber Extenders are used to connect a Remote chassis or system to a Local
chassis. In general, you need one Fiber extender per individual or group of
remote Apex chassis.

APX-FBR-EXT

Apex Fiber Extender. For use with Standard Apex chassis located more
than four meters away from local chassis. Order one pair for each remote
chassis. See

Fiber Extenders (Standard Apex Only)

.

This manual is related to the following products: