APEX — Installation and Service Manual

93

Reference Connections

Dual References - Redundant Operation

In this arrangement shown in

Figure 40

, the same video reference is

brought to the Primary and Secondary Matrix boards, and the same AES
reference is brought to both boards. If the Primary board fails the system
will switch automatically to the Secondary board.

The system will detect that the same reference signals are connected to both
boards and automatically combine Sync Bus 0 with Sync Bus 2 and Sync
Bus 1 with Sync bus 3. When configuring the output boards, only

Bus 0

and

Bus 1

are valid selections.

Figure 40. Dual References – Redundant Operation

House Video Reference (used for AES sync)

AES REF A

VID REF A

AES REF B

VID REF B

House AES Reference

Input and output

board(s) on

AES Ref

Input and output

board(s) on

Video Ref

These connections require

Matrix board B to be present

0

1

Binary ID used for assigning
reference to input and output board
with XPT board DIP switch

To next Apex chassis (or terminate)

To next Apex chassis