APEX — Installation and Service Manual

Section 3 — Installation

VDE EMI/RFI Modifications to Matrix Cables

– user-supplied matrix cables for VDE

installations require a ferrite core over each end of the cable, adjacent to the
connector as described in

Figure 49

.

Figure 49. Matrix Cable VDE Modifications

Type 43 material
0.375 inch (9.53 mm) or larger inside diameter
0.95 inch (24.13 mm) length (or longer)

Type 43 material sources
Fair-Rite, part no. 2643625102
Fair-Rite Products Corp., P.O.Box J, Commercial Row,
Wallkill, NY 12589, USA; Tel. (914) 895-2055.
Chomerics, part no. 83-10-A637-1000
Chomerics Inc., 77 Dragon Ct., Woburn, MA 01888
USA; Tel. (617) 935-4850.