beautypg.com

Configuration summary table, D in – Grass Valley 8943CF User Manual

Page 61

background image

8943CF — Instruction Manual

61

Configuration Summary Table

Table 8

provides a complete summary of the 8943CF module functions and

a comparison of the functionality available with each control type along
with the ranges and default values for each parameter and notes on each
control.

Table 8. Summary of 8943CF Configuration Functions

Function

Type

Default

Range/Choices

Resolution

Web Page/

Function Name

Local

Onboard Controls

Newton

Control

Panel

Assign Signal names for
channels 1-4

Channel 1
Channel 2
Channel 3
Channel 4

Type in name

(up to 11 characters)

I/O Config/

Signal Name

Name channel 1-4

N/A

(Defautls are used)

N/A

Reporting enable

Enabled

Enabled or Disabled

I/O Config/

Reporting Checkboxes for
Ch1, Ch 2, Ch 3, and Ch4

N/A

In1 RepLoss

In 2 RepLoss

RX2 RepLoss
RX2 RepLoss

Set Input Mode for Ch 1-4

Auto Reclock/Mute

Auto Reclock/Bypass,

Auto Reclock/Mute,

3G 2970M,

HD 1485M,

SD 270M,

Manual Bypass/HD 3G,

or Manual Bypass SD.

Setings/

Inputs

Ch 1 J1, Ch 2, J3,

Ch 3 J5, Ch 4 J7

S2 = Pos 1, Ch 1
S1 = pos 2, Ch 2
S1 = Pos 3, Ch 3
S1 = Pos 4, Ch 4

Use paddle switch S1

to cycle to desired

mode for selected

channel.

Rclk Mode

Enable Fiber outputs (Tx)

Enabled

Enabled or Disabled

Settings/

Fiber Outputs Enable

Select checkbox for Fiber TX 1,

Fiber Tx 2, Fiber Tx 3,

and Fiber Tx 4

Set onboard Jumper

OptEnable

Recall factory defaults

Settings/

Set Defaults

button

S1 = F

Push paddle switch S2

up.

Defaults