beautypg.com

Led reporting, Web browser interface, Snmp reporting – Grass Valley 8943CF User Manual

Page 57

background image

8943CF — Instruction Manual

57

Status Monitoring

LED Reporting

LEDs on the front of media modules, the Frame Monitor or 8900NET mod-
ules, and the front covers of the 8900TF/TFN and GeckoFlex FF/FFN
frames indicate status of the frame and the installed power supplies, fans
in the front covers, and module status. (The 8900TX-V/A and GeckoFlex
8900FX frames have no LED indicators on the front cover.)

LED reporting from the modules in the frame to the 8900NET module
is configurable using the 8900NET LED Reporting web page.

The Status LEDs for this module are described in Local On-board Status
Monitoring LEDs

on page 34

. LEDs for the 8900NET module are

described in the 8900NET (Net Card) Network Interface Instruction
Manual
.

Web Browser Interface

The 8900NET module controls a web browser GUI that indicates frame and
module status on the following web pages:

Frame Status web page – reports overall frame and module status in
colored graphical and text formats. Refer to

Figure 28 on page 41

for an

example.

Module Status web page (

Figure 30 on page 44

) – shows specific input

and reference signal configuration error status to the module along
with module status and information (part number, serial number, hard-
ware version, software/firmware/boot versions, and Asset number (as
assigned on the Slot Config web page).

A Status LED icon on each web page reflects the module status on the
module Status web page where warnings and faults are displayed and
is a link to the module Status web page.

SNMP Reporting

The GeckoFlex 8900 Series system uses the Simple Network Monitoring
Protocol (SNMP) internet standard for reporting status information to
remote monitoring stations. When SNMP Agent software is installed on the
8900NET module, enabled status reports are sent to an SNMP Manager
such as the Grass Valley’s NetCentral application.

Status reporting for the frame is enabled or disabled with the configuration
DIP switches on the 8900NET module. Most module status reporting items
can be enabled or disabled on individual configuration web pages.