Local mode configuration, Bed in local/remote jumper – Grass Valley 8943CF User Manual
Page 37

8943CF — Instruction Manual
37
Configuration and Monitoring
Local Mode Configuration
The module may be configured using the local on-board rotary switch and
paddle switch in conjunction with the configuration LEDs shown in
. If an 8900NET (Net Card) module is present for providing
remote configuration, refer to Remote Monitoring and Controls
Local/Remote Jumper
The on-board jumper Local/Remote jumper, J10, (
) is set at the
factory for local and remote (LOC/REM position, pins 2-3) to allow remote
control. It can be changed to lock out remote control if desired (LOC posi-
tion, pins 1-2).
TX OPT Jumper
The on-board TX OPT jumper J13, (
) enables or disables the fiber
optic transmitter outputs when the optional fiber optic transmitter SFP
devices are installed. Set jumper J13 to pins 1-2 to enable the fiber outputs
and pins 2-3 to disable. When disabled, there will be a warning on the Set-
tings web page (
) that the outputs are disabled with jumper J13.
Figure 26. On-board Configuration Switches and LEDs
Rotary Switch, S1
Paddle Switch, S2
Local/Remote Jumper
Input Op Mode
Configuration LEDs
CONF LED
TX OPT Jumper