Configuration and Monitoring

Table 3 on page 36

outlines the conditions that will result in the reported

state of the input being

Present

or

Not Present

with the onboard LEDs and the

conditions of the output based on the operating mode, the Input Presence,
the actual input standard, and the Input Reporting State

Table 2. On-board Module Status LED Names and Conditions

LED

Indication

Condition

Module Status LEDs

FAULT

(red)

Off

Normal operation, module OK.

On continuously

Module has detected an internal fault.

Flashing

Configuration problems. Check inputs and settings. Missing video input.

COMM

(yellow)

Off

No activity on frame communication bus.

Flashing

Locate Module command received by the module from a remote control system.

Pulse

(short duration

Activity present on the frame communication bus.

CONFIG

(yellow)

Off

Module is in normal operating mode, no configuration change in progress or initialization complete.

On continuously

Module is initiating or changing operating modes.

Flashing

Locate Module command received by the module from a remote control system.

PWR

(green)

Off

No power to module or module’s DC/DC converter failed.

On continuously

Normal operation, module is powered.

Input Signal Status LEDs

CH1-4

PRESENT

(green)

Off

No signal is present.

On continuously

Input signal is either, 270Mb/s, 1485Mb/s, or 2970Mb/s.

CH1-4

3G

(blue)

Off

Input signal is not 2970Mb/s.

On continuously

Input signal is 2970Mb/s.

CH1-4

HD

(green)

Off

Input signal is not 1485Mb/s.

On continuously

Input signal is 1485Mb/s.

CH1-4

SD

(yellow)

Off

Input signal is not 270Mb/s.

On continuously

Input signal is 270Mb/s.

SFP Device OPTION PRESENT LEDs

OPT MOD_1

Off

No fiber option transmitter SFP device is installed in position J6.

On continuously

Fiber optic option transmitter SFP device is installed in position J6.

OPT MOD_2

Off

No fiber option transmitter SFP device is installed in position J4.

On continuously

Fiber optic option transmitter SFP device is installed in position J4.