beautypg.com

H3C Technologies H3C SecBlade IPS Cards User Manual

Page 49

background image

42

[Sysname-Ten-GigabitEthernet] port trunk permit vlan all

[Sysname-Ten-GigabitEthernet] port connection-mode extend

[Sysname-Ten-GigabitEthernet] mac-address max-mac-count 0

[Sysname-Ten-GigabitEthernet] quit

# Save the configurations and restart the switch.

save

reboot

NOTE:

Make sure that the OAA card in slot n corresponds to the switch’s internal interface Ten-GigabitEthernet
n/0/1. For example, the OAA card in slot 8 corresponds to the switch’s internal interface
Ten-GigabitEthernet 8/0/1.

2.

Configure the SecBlade IPS card

# Configure an IP address for the management interface and enable the management interface. This
configuration is optional. By default, the IP address of the management interface is 192.168.1.1. You can

also change this IP address through the web interface.

system-view

[Sysname] interface meth0/2

[Sysname-if]ip address 192.168.0.11 255.255.255.0

[Sysname-if] undo shutdown

[Sysname-if] quit

# Log in to the web interface of the SecBlade IPS card. The username and password are both admin.

Figure 25 Log into the SecBlade IPS card

# Configure OAA.

Configure the OAA client and the internal interface and test the connectivity to the switch.