Fan tray failure – H3C Technologies H3C S5820X Series Switches User Manual
Page 83
73
•
The OAP card is compatible with the switch and can be installed in the OAP card slot.
•
The OAP card is correctly installed and well seated in the slot.
NOTE:
If the problem persists, contact your local H3C sales agent or service engineer for help.
To replace an OAP card in the OAP card slot, see "
Removing the card in the OAP card slot
" and
"
Installing an OAP card in the OAP card slot
Failure of the OAP card in an expansion interface card slot
You can use the LEDs on the OAP card to identify its operating status. For more information about the
LEDs, see the user manual that comes with the card. If your switch has a status LED for the expansion
interface card slot, you can also use the LED to identify the operating status of the card.
If the OAP card is not correctly operating, verify the following items:
•
The OAP card is compatible with the switch and can be installed in an expansion interface card
slot.
•
The OAP card is correctly installed and well seated in the slot.
NOTE:
If the problem persists, contact your local H3C sales agent or service engineer for help.
To replace the OAP card in an expansion interface card slot, see "
Installing an OAP card in an expansion interface card slot
."
Fan tray failure
You can look at the system status LED and the seven-segment LED of an S5820X switch to identify a fan
failure. If both LEDs behave as described in
, a fan failure has occurred.
Table 29 LED behaviors for fan failure
LED Mark
State
System status LED
SYS
Steady red
Seven-segment LED
Unit
The LED displays F for fan failure.
To replace a failed fan tray, follow the procedure described in “
Installing/Removing a fan tray
CAUTION:
You can replace a hot swappable fan tray without powering off the switch. To prevent overheat, replace
the failed fan tray within 2 minutes for an S5820X-28C or S5820X-28S switch.