beautypg.com

Verifying the configuration – H3C Technologies H3C S12500-X Series Switches User Manual

Page 94

background image

86

[SwitchB-Vlan-interface2] return

Verifying the configuration

# Display detailed information about the VRRP group on Switch A.

display vrrp verbose

IPv4 Virtual Router Information:

Running Mode : Standard

Total number of virtual routers : 1

Interface Vlan-interface2

VRID : 1 Adver Timer : 100

Admin Status : Up State : Master

Config Pri : 110 Running Pri : 110

Preempt Mode : Yes Delay Time : 0

Auth Type : None

Virtual IP : 192.168.0.10

Virtual MAC : 0000-5e00-0101

Master IP : 192.168.0.101

VRRP Track Information:

Track Object : 1 State : Positive Pri Reduced : 20

# Display information about track entry 1 on Switch A.

display track 1

Track ID: 1

State: Positive

Duration: 0 days 0 hours 0 minutes 32 seconds

Notification delay: Positive 0, Negative 0 (in seconds)

Tracked object:

BFD session mode: Echo

Outgoing interface: Vlan-interface2

VPN instance name: -

Remote IP: 1.1.1.2

Local IP: 1.1.1.1

# Display detailed information about the VRRP group on Switch B.

display vrrp verbose

IPv4 Virtual Router Information:

Running Mode : Standard

Total number of virtual routers : 1

Interface Vlan-interface2

VRID : 1 Adver Timer : 100

Admin Status : Up State : Backup

Config Pri : 100 Running Pri : 100

Preempt Mode : Yes Delay Time : 0

Become Master : 2200ms left

Auth Type : None

Virtual IP : 192.168.0.10

Master IP : 192.168.0.101

The output shows that when the status of track entry 1 becomes Positive, Switch A is the master, and
Switch B the backup.