[DeviceA] interface ten-gigabitethernet 1/0/1
[DeviceA-Ten-GigabitEthernet1/0/1] cfd cc service-instance 1 mep 1001 enable
[DeviceA-Ten-GigabitEthernet1/0/1] quit
# On Device B, enable the sending of CCM frames for MEP 2001 in service instance 2 on
Ten-GigabitEthernet 1/0/3.
[DeviceB] interface ten-gigabitethernet 1/0/3
[DeviceB-Ten-GigabitEthernet1/0/3] cfd cc service-instance 2 mep 2001 enable
[DeviceB-Ten-GigabitEthernet1/0/3] quit
# On Device D, enable the sending of CCM frames for MEP 4001 in service instance 2 on
Ten-GigabitEthernet 1/0/1, and enable the sending of CCM frames for MEP 4002 in service
instance 1 on Ten-GigabitEthernet 1/0/3.
[DeviceD] interface ten-gigabitethernet 1/0/1
[DeviceD-Ten-GigabitEthernet1/0/1] cfd cc service-instance 2 mep 4001 enable
[DeviceD-Ten-GigabitEthernet1/0/1] quit
[DeviceD] interface ten-gigabitethernet 1/0/3
[DeviceD-Ten-GigabitEthernet1/0/3] cfd cc service-instance 1 mep 4002 enable
[DeviceD-Ten-GigabitEthernet1/0/3] quit
# On Device E, enable the sending of CCM frames for MEP 5001 in service instance 1 on
Ten-GigabitEthernet 1/0/4.
[DeviceE] interface ten-gigabitethernet 1/0/4
[DeviceE-Ten-GigabitEthernet1/0/4] cfd cc service-instance 1 mep 5001 enable
[DeviceE-Ten-GigabitEthernet1/0/4] quit
Verifying the configuration
1.
Verify the LB function:
When the CC function detects a link fault, use the LB function to locate the fault.
# Enable LB on Device A to check the status of the link between MEP 1001 and MEP 5001 in
service instance 1.
[DeviceA] cfd loopback service-instance 1 mep 1001 target-mep 5001
Loopback to 0010-fc00-6515 with the sequence number start from 1001-43404:
Reply from 0010-fc00-6515: sequence number=1001-43404 time=5ms
Reply from 0010-fc00-6515: sequence number=1001-43405 time=5ms
Reply from 0010-fc00-6515: sequence number=1001-43406 time=5ms
Reply from 0010-fc00-6515: sequence number=1001-43407 time=5ms
Reply from 0010-fc00-6515: sequence number=1001-43408 time=5ms
Send:5 Received:5 Lost:0
After the whole network status is obtained with the CC function, use the LT function to identify the
paths between source and target MEPs or locate faults.
2.
Verify the LT function:
# Identify the path between MEP 1001 and MEP 5001 in service instance 1 on Device A.
[DeviceA] cfd linktrace service-instance 1 mep 1001 target-mep 5001
Linktrace to MEP 5001 with the sequence number 1001-43462:
MAC Address TTL Last MAC Relay Action
0010-fc00-6515 63 0010-fc00-6512 Hit
- H3C S5560 Series Switches H3C WX6000 Series Access Controllers H3C WX5000 Series Access Controllers H3C WX3000 Series Unified Switches H3C LSWM1WCM10 Access Controller Module H3C LSWM1WCM20 Access Controller Module H3C LSQM1WCMB0 Access Controller Module H3C LSRM1WCM2A1 Access Controller Module H3C LSBM1WCM2A0 Access Controller Module H3C S9800 Series Switches H3C S5130 Series Switches H3C S5120 Series Switches H3C S6300 Series Switches H3C S5820V2 Series Switches H3C S5830 Series Switches H3C S5830V2 Series Switches H3C S3600V2 Series Switches