Configuring link monitoring, Configuring errored symbol event detection, Ethernet oam configuration task list – H3C Technologies H3C S12500-X Series Switches User Manual
Page 13: Configuring basic ethernet oam functions
5
You can configure this command in system view or port view. The configuration in system view takes effect
on all ports, and the configuration in port view takes effect on the specified port. For a port, the
configuration in port view takes precedence.
After the timeout timer of an Ethernet OAM connection expires, the local OAM entity ages out its
connection with the peer OAM entity, causing the OAM connection to disconnect. To keep the Ethernet
OAM connections stable, H3C recommends setting the connection timeout timer to be at least five times
the handshake packet transmission interval.
To configure the Ethernet OAM connection detection timers globally:
Step Command
Remarks
1.
Enter system view.
System-view
N/A
2.
Configure the Ethernet OAM
handshake packet
transmission interval.
oam global timer hello interval
The default is 1000 milliseconds.
3.
Configure the Ethernet OAM
connection timeout timer.
oam global timer keepalive
interval
The default is 5000 milliseconds.
To configure the Ethernet OAM connection detection timers on a port:
Step Command
Remarks
1.
Enter system view.
System-view
N/A
2.
Enter Layer 2/Layer 3 Ethernet
port view.
interface interface-type
interface-number
N/A
3.
Configure the Ethernet OAM
handshake packet
transmission interval.
oam timer hello interval
By default, an interface uses the
value configured globally.
4.
Configure the Ethernet OAM
connection timeout timer.
oam timer keepalive interval
By default, an interface uses the
value configured globally.
Configuring link monitoring
After Ethernet OAM connections are established, the link monitoring periods and thresholds configured
in this section automatically take effect on all Ethernet ports.
Configuring errored symbol event detection
An errored symbol event occurs when the number of detected symbol errors in the detection window
(specified number of received symbols) exceeds the predefined threshold.
You can configure this command in system view or port view. The configuration in system view takes effect
on all ports, and the configuration in port view takes effect on the specified port. For a port, the
configuration in port view takes precedence.
To configure errored symbol event detection globally:
- H3C S5560 Series Switches H3C WX6000 Series Access Controllers H3C WX5000 Series Access Controllers H3C WX3000 Series Unified Switches H3C LSWM1WCM10 Access Controller Module H3C LSWM1WCM20 Access Controller Module H3C LSQM1WCMB0 Access Controller Module H3C LSRM1WCM2A1 Access Controller Module H3C LSBM1WCM2A0 Access Controller Module H3C S9800 Series Switches H3C S5130 Series Switches H3C S5120 Series Switches H3C S6300 Series Switches H3C S5820V2 Series Switches H3C S5830 Series Switches H3C S5830V2 Series Switches H3C S3600V2 Series Switches