You can configure this command in system view or port view. The configuration in system view takes effect

on all ports, and the configuration in port view takes effect on the specified port. For a port, the
configuration in port view takes precedence.
After the timeout timer of an Ethernet OAM connection expires, the local OAM entity ages out its

connection with the peer OAM entity, causing the OAM connection to disconnect. To keep the Ethernet

OAM connections stable, H3C recommends setting the connection timeout timer to be at least five times
the handshake packet transmission interval.
To configure the Ethernet OAM connection detection timers globally:

Step Command

Remarks

1.

Enter system view.

System-view

N/A

2.

Configure the Ethernet OAM
handshake packet

transmission interval.

oam global timer hello interval

The default is 1000 milliseconds.

3.

Configure the Ethernet OAM
connection timeout timer.

oam global timer keepalive
interval

The default is 5000 milliseconds.

To configure the Ethernet OAM connection detection timers on a port:

Step Command

Remarks

1.

Enter system view.

System-view

N/A

2.

Enter Layer 2/Layer 3 Ethernet

port view.

interface interface-type
interface-number

N/A

3.

Configure the Ethernet OAM
handshake packet

transmission interval.

oam timer hello interval

By default, an interface uses the
value configured globally.

4.

Configure the Ethernet OAM

connection timeout timer.

oam timer keepalive interval

By default, an interface uses the
value configured globally.

Configuring link monitoring

After Ethernet OAM connections are established, the link monitoring periods and thresholds configured
in this section automatically take effect on all Ethernet ports.

Configuring errored symbol event detection

An errored symbol event occurs when the number of detected symbol errors in the detection window
(specified number of received symbols) exceeds the predefined threshold.
You can configure this command in system view or port view. The configuration in system view takes effect

on all ports, and the configuration in port view takes effect on the specified port. For a port, the

configuration in port view takes precedence.
To configure errored symbol event detection globally: