Step Command
Remarks
5.
Configure the multi-hop
detection time multiplier.
bfd multi-hop detect-multiplier
value
The default setting is 5.
6.
Configure the minimum
interval for receiving multi-hop
BFD control packets.
bfd multi-hop min-receive-interval
value
The default setting is 400
milliseconds.
7.
Configure the minimum
interval for transmitting
multi-hop BFD control packets.
bfd multi-hop
min-transmit-interval value
The default setting is 400
milliseconds.
Displaying and maintaining BFD
Execute the display command in any view and the reset command in user view.
Task Command
Display BFD session information.
display bfd session [ discriminator value | verbose ]
Clear BFD session statistics.
reset bfd session statistics
- H3C S5560 Series Switches H3C WX6000 Series Access Controllers H3C WX5000 Series Access Controllers H3C WX3000 Series Unified Switches H3C LSWM1WCM10 Access Controller Module H3C LSWM1WCM20 Access Controller Module H3C LSQM1WCMB0 Access Controller Module H3C LSRM1WCM2A1 Access Controller Module H3C LSBM1WCM2A0 Access Controller Module H3C S9800 Series Switches H3C S5130 Series Switches H3C S5120 Series Switches H3C S6300 Series Switches H3C S5820V2 Series Switches H3C S5830 Series Switches H3C S5830V2 Series Switches H3C S3600V2 Series Switches