13
Figure 3 Procedure of creating MIPs
demonstrates a grading example of the CFD module. Four levels of MDs (0, 2, 3, and 5) are
designed. The bigger the number, the higher the level and the larger the area covered. MPs are
configured on the ports of Device A through Device F. Port 1 of Device B is configured with the following
MPs: a level 5 MIP, a level 3 inward-facing MEP, a level 2 inward-facing MEP, and a level 0
outward-facing MEP.
Figure 4 CFD grading example
MEP list
A MEP list is a collection of local MEPs allowed to be configured and the remote MEPs to be monitored
in the same MA. It lists all the MEPs configured on different devices in the same MA. The MEPs all have
unique MEP IDs. When a MEP receives from a remote device a continuity check message (CCM) that
carries a MEP ID not included in the MEP list of the MA, it drops the message.
- H3C S5560 Series Switches H3C WX6000 Series Access Controllers H3C WX5000 Series Access Controllers H3C WX3000 Series Unified Switches H3C LSWM1WCM10 Access Controller Module H3C LSWM1WCM20 Access Controller Module H3C LSQM1WCMB0 Access Controller Module H3C LSRM1WCM2A1 Access Controller Module H3C LSBM1WCM2A0 Access Controller Module H3C S9800 Series Switches H3C S5130 Series Switches H3C S5120 Series Switches H3C S6300 Series Switches H3C S5820V2 Series Switches H3C S5830 Series Switches H3C S5830V2 Series Switches H3C S3600V2 Series Switches