Configuring errored frame period event detection, Configuring errored frame seconds event detection – H3C Technologies H3C S12500-X Series Switches User Manual
Page 15
7
Step Command
Remarks
4.
Configure the errored frame
event triggering threshold.
oam errored-frame threshold
threshold-value
By default, an interface uses the
value configured globally.
Configuring errored frame period event detection
An errored frame period event occurs when the number of times that frame errors in the detection window
(specified number of received frames) are detected exceeds the predefined threshold.
You can configure this command in system view or port view. The configuration in system view takes effect
on all ports, and the configuration in port view takes effect on the specified port. For a port, the
configuration in port view takes precedence.
To configure errored frame period event detection globally:
Step Command
Remarks
1.
Enter system view.
system-view
N/A
2.
Configure the errored frame
period event detection
window.
oam global errored-frame-period
window window-value
By default, the errored frame
period event detection window is
10000000.
3.
Configure the errored frame
period event triggering
threshold.
oam global errored-frame-period
threshold threshold-value
By default, the errored frame
period event triggering threshold is
1.
To configure errored frame period event detection on a port:
Step Command
Remarks
1.
Enter system view.
system-view
N/A
2.
Enter Layer 2/Layer 3 Ethernet
port view.
interface interface-type
interface-number
N/A
3.
Configure the errored frame
period event detection
window.
oam errored-frame-period
window window-value
By default, an interface uses the
value configured globally.
4.
Configure the errored frame
period event triggering
threshold.
oam errored-frame-period
threshold threshold-value
By default, an interface uses the
value configured globally.
Configuring errored frame seconds event detection
CAUTION:
Make sure the errored frame seconds triggering threshold is less than the errored frame seconds detection
window. Otherwise, no errored frame seconds event can be generated.
An errored frame seconds event occurs when the number of times that errored frame seconds are
detected on a port in the detection window (specified detection interval) exceeds the predefined
threshold.
- H3C S5560 Series Switches H3C WX6000 Series Access Controllers H3C WX5000 Series Access Controllers H3C WX3000 Series Unified Switches H3C LSWM1WCM10 Access Controller Module H3C LSWM1WCM20 Access Controller Module H3C LSQM1WCMB0 Access Controller Module H3C LSRM1WCM2A1 Access Controller Module H3C LSBM1WCM2A0 Access Controller Module H3C S9800 Series Switches H3C S5130 Series Switches H3C S5120 Series Switches H3C S6300 Series Switches H3C S5820V2 Series Switches H3C S5830 Series Switches H3C S5830V2 Series Switches H3C S3600V2 Series Switches