beautypg.com

Configuration procedure – H3C Technologies H3C S12500-X Series Switches User Manual

Page 93

background image

85

Figure 23 Network diagram

Configuration procedure

1.

Create VLANs and assign corresponding ports to them. Configure the IP address of each VLAN
interface as shown in

Figure 23

. (Details not shown.)

2.

On Switch A, configure the source address of BFD echo packets as 10.10.10.10.

system-view

[SwitchA] bfd echo-source-ip 10.10.10.10

3.

On Switch A, create track entry 1 to be associated with the BFD session to check whether the uplink

device with the IP address 1.1.1.2 is reachable.

[SwitchA] track 1 bfd echo interface vlan-interface 3 remote ip 1.1.1.2 local ip

1.1.1.1

4.

On Switch A, create VRRP group 1, and configure the virtual IP address of the group as
192.168.0.10. Configure the priority of Switch A in VRRP group 1 as 110. Configure VRRP group

1 to monitor the status of track entry 1. When the status of the track entry becomes Negative, the

priority of Switch A decreases by 20.

[SwitchA] interface vlan-interface 2

[SwitchA-Vlan-interface2] vrrp vrid 1 virtual-ip 192.168.0.10

[SwitchA-Vlan-interface2] vrrp vrid 1 priority 110

[SwitchA-Vlan-interface2] vrrp vrid 1 track 1 reduced 20

[SwitchA-Vlan-interface2] return

5.

On Switch B, create VRRP group 1, and configure the virtual IP address of the group as

192.168.0.10.

system-view

[SwitchB] interface vlan-interface 2

[SwitchB-Vlan-interface2] vrrp vrid 1 virtual-ip 192.168.0.10

Internet

Master

uplink device

Backup

uplink device

Uplink

Virtual router

Virtual IP address:

192.168.0.10

Vlan-int2

192.168.0.101/24

Vlan-int2
192.168.0.102/24

Switch A

Master

Switch B

Backup

Vlan-int3

1.1.1.1/24

Vlan-int3

1.1.1.2/24

L2 switch

Uplink

VRRP packets

BFD probe packets