6
Step Command
Remarks
1.
Enter system view.
system-view
N/A
2.
Configure the errored symbol
event detection window.
oam global errored-symbol-period
window window-value
By default, the errored symbol
event detection window is
100000000.
3.
Configure the errored symbol
event triggering threshold.
oam global errored-symbol-period
threshold threshold-value
By default, the errored symbol
event triggering threshold is 1.
To configure errored symbol event detection on a port:
Step Command
Remarks
1.
Enter system view.
system-view
N/A
2.
Enter Layer 2/Layer 3 Ethernet
port view.
interface interface-type
interface-number
N/A
3.
Configure the errored symbol
event detection window.
oam errored-symbol-period
window window-value
By default, an interface uses the
value configured globally.
4.
Configure the errored symbol
event triggering threshold.
oam errored-symbol-period
threshold threshold-value
By default, an interface uses the
value configured globally.
Configuring errored frame event detection
An errored frame event occurs when the number of times that error frames in the detection window
(specified detection interval) are detected exceeds the predefined threshold.
You can configure this command in system view or port view. The configuration in system view takes effect
on all ports, and the configuration in port view takes effect on the specified port. For a port, the
configuration in port view takes precedence.
To configure errored frame event detection globally:
Step Command
Remarks
1.
Enter system view.
system-view
N/A
2.
Configure the errored frame
event detection window.
oam global errored-frame window
window-value
By default, the errored frame event
detection window is 1000
milliseconds.
3.
Configure the errored frame
event triggering threshold.
oam global errored-frame
threshold threshold-value
By default, the errored frame event
triggering threshold is 1.
To configure errored frame event detection on a port:
Step Command
Remarks
1.
Enter system view.
system-view
N/A
2.
Enter Layer 2/Layer 3 Ethernet
port view.
interface interface-type
interface-number
N/A
3.
Configure the errored frame
event detection window.
oam errored-frame window
window-value
By default, an interface uses the
value configured globally.
- H3C S5560 Series Switches H3C WX6000 Series Access Controllers H3C WX5000 Series Access Controllers H3C WX3000 Series Unified Switches H3C LSWM1WCM10 Access Controller Module H3C LSWM1WCM20 Access Controller Module H3C LSQM1WCMB0 Access Controller Module H3C LSRM1WCM2A1 Access Controller Module H3C LSBM1WCM2A0 Access Controller Module H3C S9800 Series Switches H3C S5130 Series Switches H3C S5120 Series Switches H3C S6300 Series Switches H3C S5820V2 Series Switches H3C S5830 Series Switches H3C S5830V2 Series Switches H3C S3600V2 Series Switches