beautypg.com

Configuring link monitoring, Configuring errored symbol event detection – H3C Technologies H3C S12500-X Series Switches User Manual

Page 16

background image

8

You can configure this command in system view or port view. The configuration in system view takes effect

on all ports, and the configuration in port view takes effect on the specified port. For a port, the
configuration in port view takes precedence.
To configure errored frame seconds event detection globally:

Step Command

Remarks

1.

Enter system view.

system-view

N/A

2.

Configure the errored frame

seconds event detection
window.

oam global errored-frame-seconds
window window-value

By default, the errored frame
seconds event detection window

is 60000 milliseconds.

3.

Configure the errored frame
seconds event triggering

threshold.

oam global errored-frame-seconds
threshold threshold-value

By default, the errored frame
seconds event triggering
threshold is 1.

To configure errored frame seconds event detection on a port:

Step Command

Remarks

1.

Enter system view.

system-view

N/A

2.

Enter Layer 2/Layer 3 Ethernet
port view.

interface interface-type
interface-number

N/A

3.

Configure the errored frame

seconds event detection
window.

oam errored-frame-seconds
window window-value

By default, an interface uses the
value configured globally.

4.

Configure the errored frame

seconds event triggering
threshold.

oam errored-frame-seconds
threshold threshold-value

By default, an interface uses the
value configured globally.

Configuring the action a port takes after it receives

an Ethernet OAM event from the remote end

This feature enables a port to log events and automatically terminate the OAM connection and set the
link state to down.
To configure the action the port takes after it receives an Ethernet OAM event from the remote end:

Step Command

Remarks

1.

Enter system view.

system-view N/A

2.

Enter Layer 2/Layer 3 Ethernet

port view.

interface interface-type
interface-number

N/A

3.

Configure the action the port
takes after it receives an

Ethernet OAM event from the
remote end.

oam remote-failure
{ connection-expired |

critical-event | dying-gasp |

link-fault } action error-link-down

By default, the port only logs the
Ethernet OAM event it receives
from the remote end.