124

Untagged ports:

Ten-GigabitEthernet1/0/1 Ten-GigabitEthernet1/0/2

Ten-GigabitEthernet1/0/5

VLAN ID: 2

VLAN type: Static

Private VLAN type: Secondary

Route interface: Not configured

Description: VLAN 0002

Name: VLAN 0002

Tagged ports: None

Untagged ports:

Ten-GigabitEthernet1/0/2 Ten-GigabitEthernet1/0/5

VLAN ID: 3

VLAN type: Static

Private VLAN type: Secondary

Route interface: Not configured

Description: VLAN 0003

Name: VLAN 0003

Tagged Ports: None

Untagged Ports:

Ten-GigabitEthernet1/0/1 Ten-GigabitEthernet1/0/5

Private VLAN configuration example in trunk promiscuous

mode

Network requirements

As shown in

Figure 35

:

VLAN 5 and VLAN 10 are primary VLANs on Device B. The uplink port Ten-GigabitEthernet 1/0/1
permits the packets from VLAN 5 and VLAN 10 to pass through tagged.

On Device B, the downlink port Ten-GigabitEthernet 1/0/2 permits secondary VLAN 2, and the
downlink port Ten-GigabitEthernet 1/0/3 permits secondary VLAN 3. Secondary VLANs 2 and 3

are associated with primary VLAN 5.

On Device B, the downlink port Ten-GigabitEthernet 1/0/6 permits secondary VLAN 6, and the
downlink port Ten-GigabitEthernet 1/0/8 permits secondary VLAN 8. Secondary VLANs 6 and 8

are associated with primary VLAN 10.

Device A is aware of only VLANs 5 and 10 on Device B.