118
{
Configure Host B and Host D to be on the same IP subnet. For example, 192.168.200.0/24.
Verifying the configuration
# Verify that Host A and Host C can ping each other, but they both fail to ping Host B.
# Verify that Host B and Host D can ping each other, but they both fail to ping Host A.
# Verify that VLANs 100 and 200 are correctly configured on Device A.
[DeviceA-Ten-GigabitEthernet1/0/3] display vlan 100
VLAN ID: 100
VLAN type: Static
Route interface: Not configured
Description: VLAN 0100
Name: VLAN 0100
Tagged ports:
Ten-GigabitEthernet1/0/3
Untagged ports:
Ten-GigabitEthernet1/0/1
[DeviceA-Ten-GigabitEthernet1/0/3] display vlan 200
VLAN ID: 200
VLAN type: Static
Route interface: Not configured
Description: VLAN 0200
Name: VLAN 0200
Tagged ports:
Ten-GigabitEthernet1/0/3
Untagged ports:
Ten-GigabitEthernet1/0/2