1 job computer technical data, 2 auxiliary input technical data, 18 end of life disposal – ARAG GCS 3200 User Manual
Page 44: Technical data

44
17.1
Job computer technical data
Description
Power supply voltage
9 ÷ 15 Vdc
Consumption (valves excluded)
300 mA
Working temperature
-20 °C ÷ +70 °C
-4 °F ÷ +158 °F
Digital inputs
for open collector sensors: max 2000 imp/s
Analog input
4 ÷ 20 mA
Weight
1330 g (RCU without harness)
Protection against polarity inversion
•
Protection against short-circuit
•
Tab. 16
17.2
Auxiliary Input technical data
Descrizione
Power supply voltage
9 ÷ 15 Vdc
Consumption (valves excluded)
max 250 mA
Working temperature
0 °C ÷ +50 °C
+32 °F ÷ +122 °F
Weight
1080 g (without harness)
Protection against polarity inversion
•
Protection against short-circuit
•
Tab. 17
18
end of life disposal
Dispose of the system in compliance with the established legislation in the country of use.