3 nozzles setup, Tab. 9, User setting – ARAG GCS 3200 User Manual
Page 29

29
13.3
Nozzles setup
Fig. 60
Fig. 61
Features that can be set for each USER nozzle (Fig. 61):
- value of minimum and maximum reference pressure (
bar
or
PSI
).
- value of the reference flow rate (
l/min
or
GPM
) that allows the ISOBUS system to calculate the pressure even without a pressure sensor.
WARNING: “ISO” NOZZLES CAN NOT BE MODIFIED.
Data to be set for each type of nozzle (ISO included):
- alarm value of minimum reference pressure
- alarm value of maximum reference pressure
The rate of the nozzle being used allows the ISOBUS system to calculate the pressure without a pressure sensor.
noZZles
Nozzle colour
ISO code
Unit of measurement
METRIC
Unit of measurement
US
The values for pressure
bar
and flowrate
l/min
can be modified for “USER”
nozzles ONLY, not for “ISO” nozzles.
Flowrate
(l/min)
Pressure
(bar)
Flowrate
(GPM)
Pressure
(PSI)
Orange
ISO01
0,40
3,0
0,100
40
Green
ISO015
0,60
3,0
0,150
40
Yellow
ISO02
0,80
3,0
0,200
40
Lilac
ISO025
1,00
3,0
0,250
40
Blue
ISO03
1,20
3,0
0,300
40
Red
ISO04
1,60
3,0
0,400
40
Brown
ISO05
2,00
3,0
0,500
40
Gray
ISO06
2,40
3,0
0,600
40
White
ISO08
3,20
3,0
0,800
40
Light blue
ISO10
4,00
3,0
1,000
40
Light green
ISO15
6,00
3,0
1,500
40
Black
ISO20
8,00
3,0
2,000
40
Type A
--
0,98
5,0
0,026
73
User data:
0,01 ÷ 99,9
Type B
--
2,01
5,0
0,053
73
Type C
--
2,99
5,0
0,079
73
Type D
--
4,01
5,0
0,106
73
Tab. 9
USER SETTING