Technical data – ARAG GCS 3200 User Manual
Page 43

43
• User setting
data
description
Min.
Max.
udM
notes
Speed
*
Source
--
--
--
Values that can be set: Wheel sensor, GPS.
Selected wheel type
--
--
--
Possibility to save up to three types of wheel
Wheels setting
--
--
--
Groups sub-menus: Constant calculation, Wheel constant
Constant calculation
--
--
--
Value that can be set: Manual, Automatic
Wheel constant
0,01
150
cm/imp
Number of constant to be set: 1 ÷ 3
Counting distance
20
1000
m
Distance to be travelled during automatic calculation of the
constant
Jobs setup
Available job selection
--
--
--
Possible setting: 01 ÷ 20
Application rate
Disabled 9999
Metric: l/ha
US: gpa
--
Nozzle
--
--
--
Possible settings:
ISO 01 ÷ 20, Type A ÷ E
Nozzles setup
Flowrate
0,01
99,99
l/min
Value can ONLY be edited for custom-made nozzles
Pressure
0,1
99,9
bar
Minimum pressure alarm
Disabled 99,9
bar
Value can be edited for custom-made and ISO nozzles
Maximum pressure alarm
Disabled 99,9
bar
Working limits
Nozzles wear check
Disabled
50
%
--
Min. spraying speed
Disabled 999,9
km/h
--
Regulation lock type
--
--
--
Groups the options: Disabled, Min. regulation speed,
Min. regulation pressure
Min. spraying speed
Disabled 999,99
km/h
--
Min. regulation pressure
Disabled 99,9
bar
--
Flowrate correct. factor
0,01
10,00
--
--
Test
Speed simulation
--
--
--
Values that can be set: No, Yes
Tab. 13
• Delivery values
data
description
Min.
Max.
udM
Applied quantity
Quantity of fluid dispensed per
unit of surface area
0
9999
l/ha
Speed
Vehicle speed
0
99
km/h
Flowrate
Quantity of fluid dispensed per
unit of time
0
999,9
l/min
Pressure
Spraying pressure
0
999,9
bar
Tank level
Fluid level left in tank
0
9999
l
Rev counter
RPM
0
9999
RPM
Tab. 14
• Counters
data
description
Min.
Max.
udM
Covered area
Covered area
0,000
99999
ha
Applied quantity
Dispensed fluid
0
99999
l
Time
Time worked
00:00
99999
h
Distace traveled
Distance travelled
0,000
99999
km
Tab. 15
*
imp = pulse
turn = giro
TECHNICAL DATA