6 flowmeter, Tab. 6, Advanced setup – ARAG GCS 3200 User Manual
Page 20

20
12.6
Flowmeter
Fig. 34
Fig. 35
Flowmeter out of range
Rate alarm
Set the installed flowmeter by selecting it from the list (as indicated in Tab. 6).
The relevant configuration data will be loaded automatically and can be customized.
Type
:
indicate the type of installed flowmeter (Tab. 6).
Min. flowrate alarm
Max. flowrate alarm
The flowmeter rate alarms (minimum or maximum) activate when, during the treatment, the flowmeter rate does not respect the set limits.
For the procedure to be followed in case of alarms, please refer to Par. 16.1 - Operation errors.
Constant
: indicate the constant of the installed flowmeter.
When the option
None
is selected, the items
Min. flowrate alarm Max. flowrate alarm
and Constant
are not longer visible on
the display (Fig. 35).
orion flowMeters
TYPE
UNIT OF MEASUREMENT - METRIC
UNIT OF MEASUREMENT - US
The default values can be modified.
Constant
(pls/l)
Min. rate
(l/min)
Max. rate
(l/min)
Constant
(pls/gal)
Min. rate
GPM
Max. rate
GPM
4621xA0xxxx
6000
0,5
10,0
22710
0,13
2,60
4621xA1xxxx
3000
1,0
20,0
11355
0,30
5,00
4621xA2xxxx
1200
2,5
50,0
4520
0,60
13,00
4621xA3xxxx
600
5,0
100,0
2271
1,30
26,00
462xxA4xxxx
300
10,0
200,0
1135
2,60
53,00
4622xA5xxxx
150
20,0
400,0
568
5,00
106,00
4622xA6xxxx
100
30,0
600,0
370
8,00
158,00
Other...
625
10,0
100,0
2366
2,60
53,00
Tab. 6
ADVANCED SETUP