Set tank capacity and range value:
Capacity
: indicate the tank capacity.
Minimum level alarm.
: indicate the range value.
The tank alarm activates when during the treatment the tank level falls below the set value.
12.10
Filling flowmeter
Fig. 42
Fig. 43
The filling flowmeter installed in the system allows displaying the tank filling data in real time.
Type
: indicate the filling flowmeter installed and the relevant data.
Tab. 8 contains the values that will be automatically set by selecting the flowmeter code. Nevertheless the constant can be modified.
Constant
: indicate the constant of the installed filling flowmeter.
orion flowMeters
TYPE
UNIT OF MEASUREMENT - METRIC
UNIT OF MEASUREMENT - US
The default values can be modified.
Constant
(pls/l)
Min. rate
(l/min)
Max. rate
(l/min)
Constant
(pls/gal)
Min. rate
GPM
Max. rate
GPM
462xxA4xxxx
300
10,0
200,0
1135
2,60
53,00
4622xA5xxxx
150
20,0
400,0
568
5,00
106,00
4622xA6xxxx
100
30,0
600,0
370
8,00
158,00
Other...
625
10,0
100,0
2366
2,60
53,00
Tab. 8