11 rev counter (rpm sensor), 12 foam marker, 11 rev counter (rpm sensor) 12.12 foam marker – ARAG GCS 3200 User Manual
Page 23: Advanced setup

23
ADVANCED SETUP
12.11
Rev counter (RPM Sensor)
Fig. 44
Fig. 45
Set the data of the RPM sensor (if installed in the system):
Constant
: indicate the constant of the installed RPM sensor.
Minimum speed alarm
Maximum speed alarm
The speed alarms (minimum or maximum) activate when the measured RPM
exceed the set limits.
The control is active only when the spraying is active (main switch
ON).
Increase rotation speed!
Reduce rotation speed!
Speed alarms
If the RPM sensor is
Disabled
, items
Min. speed alarm
and
Max.
speed alarm
(Fig. 45) are no longer visible on the display.
12.12
Foam Marker
Fig. 46
Foam marker
RIGHT
Foam marker
LEFT
Fig. 47
Set foam marker operating mode:
Manual
Foam marker is operated from the dedicated keys (Fig. 47).
Semi-autom.
Main switch ON --> foam marker ON
Main switch OFF --> foam marker OFF
Automatic
Main switch ON --> foam marker ON
Main switch OFF --> foam marker OFF
Whenever the foam marker is ON, the active side changes automatically.