Pressure sensor zero value, Advanced setup "implement – ARAG Bravo 400S Crop sprayer User Manual
Page 41
41
• Pressure sensor zero value
Fig. 139
To access this menu, the pressure sensor must be enabled (
, par. 10.1.4)
In case a pressure value other than zero is displayed
despite the absence of pressure inside the circuit,
it is necessary to perform zero calibration of the sensor.
Before carrying out any operation disable the pump by disconnecting it from the power supply.
Make sure that the pump is correctly disabled, then open the main valve and all section
valves.
Fig. 140
Fig. 141
1 Select
Pressure sensor zero value
OK
.
2 The message in Fig. 140 is displayed: follow
the instructions, then start the procedure by
pressing
OK
.
3 Press
OK
to reset the pressure sensor
residual signal.
Value out of range!
If this alarm is displayed, faulty pressure
values have been detected: check the
sensor operation.
If the problem persists, check for residual
pressure in the system.