17 technical data, 1 the data and unit of measurement shown, Technical data – ARAG Bravo 400S Crop sprayer User Manual
Page 103
103
17
TECHNICAL DATA
DESCRIPTION
Bravo 400S
Display
LCD 5.7", 65000 colors, 500 cd/m
2
Rated supply voltage
12 Vdc (9 ÷ 15 Vdc)
Consumption (valves excluded)
monitor: 0.4 A / hydraulic RCU: 1.5 A
Operating temperature
0 °C ÷ 45 °C
+32 °F ÷ +113 °F
Storage temperature
-20 °C ÷ 45 °C
-4 °F ÷ +113 °F
Digital inputs
for open collector sensors: max 2000 imp*/s
Analog input
4 ÷ 20 mA
Weight (without cables)
monitor: 1567 g (Bravo code 4674A2D21)
RCU: 1143 g
SD card reader
•
2 USB 2.0 ports
HOST
Protection against polarity inversion
•
Protection against short-circuit
•
17.1
The data and unit of measurement shown
Implement
Menu
Data
Min. Max.
UoM
DEFAULT
Other values that can be set / Notes
Sections
configuration
Spray spots spacing
1
1000
cm
50 cm
0.39 393.70 inches
19.68 inches
Number of sections
1
13
no
7
Selection during guided setup
Number of spraying points
--
--
--
35
Total value of spraying points installed to boom
Boom width
--
--
m
17.50 m
Value calculated automatically by multiplying the number of
spraying points by their distance
--
--
ft
57.41 ft m
Section 1 ÷ 13
1
50
no.
5
Number of spraying points for each section
Flowmeter
Type
--
--
--
Orion
462xxA4xxxx
Orion 4621xA0xxxx, Orion 4621xA1xxxx, Orion 4621xA2xxxx,
Orion 4621xA3xxxx, Orion 4622xA5xxxx, Orion 4622xA6xxxx,
Wolf 462x2xxx, Wolf 462x3xxx, Wolf 462x4xxx, Wolf 462x5xxx,
Wolf 462x7xxx, Other
Constant
1
32000
pls*/l
--
Fixed settings for each flowmeter except Other
4
32000 pls*/gal
--
Minimum flowrate
0.1
999.9
l/min
--
0.1
264.1
GPM
--
Maximum flowrate
0.1
999.9
l/min
--
0.1
264.1
GPM
--
Filling flowmeter
Type
--
--
--
Orion
462xxA4xxxx
Orion 4622xA5xxxx, Orion 4622xA6xxxx,
Wolf 462x4xxx, Wolf 462x5xxx, Wolf 462x7xxx, Other
Constant
1
32000
pls*/l
--
Fixed settings for each flowmeter except Other
4
32000 pls*/gal
--
Minimum flowrate
0.1
999.9
l/min
--
0.1
264.1
GPM
--
Maximum flowrate
0.1
999.9
l/min
--
0.1
264.1
GPM
--
Pressure sensor
Activation status
--
--
--
Disabled
Enabled
Type
--
--
--
466113.200
466113.500, Other
Maximum pressure
0.1
150.0
bar
--
Fixed settings for each sensor except Other
1
2175
PSI
--
TECHNICAL DATA
* pls = pulse
CONTINUES > > >