Output value screen, Control period, Set point 0 ((c/(f ) – AEC WD 350 through WD3000 Dehumidifying Dryers User Manual

Page 66: Set point 1

background image

Output Value Screen

Screens manipulated output variable % from 0 to 100.0%

Control

Period

Set this value to match the characteristics of the process: a short control period for a fast moving
process; a long control period for a slow moving process. The factory default setting is 20
seconds
. Please note that a control period of less than 20 seconds may shorten the life of a relay
output.

Output Value: 50.0%

20 Sec. Control Period

10 Sec. Control Period


Set Point 0 (

°

C/

°

F )

Do not install a pre-set value at this set point. It tracks the SV value on Level 0. This value is
Temperature Set Point

1

, which you select by the switch on the front panel of the dryer. This

feature is found only on dryers with the dual set point option.

Set Point 1

Use

and

to set the value for set point to

1

. It is

possible to set the value regardless of whether the set
value presently selected is on

or

. This is

Temperature Set Point

2

when selected by the set point

switch on the dryer front panel. This feature is found only
on dryers with the dual set point option. The set point can
be selected by short-circuiting the EV1 terminals
(terminals

17

and

20

) on the temperature controller.

20

17

Set point 1

20

17

Set point 0